輸尿管腎鏡維修注意事項
Precautions for ureterorenoscope maintenance
1、輸尿管腎鏡是非常嬌貴的儀器,怕摔、怕壓、怕震,因此,使用時應非常仔細,不用時,應有專人負責保管。
1. Ureterorenoscope is a very delicate instrument, which is afraid of falling, pressure and shock. Therefore, it should be used very carefully. When not in use, it should be kept by a specially assigned person.
2、每次使用后應用清水洗凈,用紗布擦干。內窺鏡兩端玻璃表面用蘸有少量無水酒精的小棉簽輕輕擦拭干凈,放干燥處保存。
2. After each use, clean with clean water and dry with gauze. The glass surfaces at both ends of the endoscope shall be gently wiped clean with a small cotton swab dipped in a small amount of anhydrous alcohol and stored in a dry place.
3、導光束不可過分彎曲,彎曲半徑不得少于5cm。否則易折斷光導纖維,影響透光率。
3. The guide beam shall not be excessively bent, and the bending radius shall not be less than 5cm. Otherwise, it is easy to break the optical waveguide and affect the light transmittance.
4、每次手術完成后,應將水閥旋開螺母,抽出閥芯,擦干凈后涂上醫用硅油或醫用凡士林潤滑,以防銹蝕。
4. After each operation, loosen the nut of the water valve, pull out the valve core, wipe it clean and apply medical silicone oil or medical Vaseline for lubrication to prevent corrosion.
5、包裝箱內各器械與內窺鏡應擺放整齊,切不可交叉重疊放置,以防壓壞鏡管。
5. All instruments and endoscopes in the packing box shall be placed neatly, and shall not be placed in a cross or overlapping manner to prevent crushing the lens tube.
6、輸尿管腎鏡及手術器械除不能用煮沸的高壓蒸汽外,其他常規液均可,可用5%福爾馬林液或者酒精浸泡15—30分鐘,或用福爾馬林蒸汽,再用水沖洗干凈。
6. Ureterorenoscope and surgical instruments can be sterilized with other conventional disinfectants except boiling high-pressure steam. They can be soaked in 5% formalin or alcohol for 15-30 minutes, or sterilized with formalin steam and rinsed with sterile water.
7、
內窺鏡設備維修人員提醒,在該設備的運輸過程應防沖擊、劇烈震動和潮濕。
7. The maintenance personnel of endoscope equipment remind that the equipment should be protected from impact, severe vibration and humidity during transportation.
8、儲存環境:溫度—40℃~55℃,相對濕度不大于80%,無腐蝕性氣體,通風良好的室內。
8. Storage environment: temperature - 40 ℃ ~55 ℃, relative humidity no more than 80%, no corrosive gas, well ventilated room.
輸尿管腎鏡維修的特色服務
Characteristic service of ureterorenoscope repair
1、輸尿管腎鏡維修時間迅速不影響手術
1. Rapid repair time of ureterorenoscope does not affect operation
維修工期為五個工作日到十五個工作日,修復后在非人為損壞的情況下,保修期為六個月到十二個月(根據醫療器械的類別制定)。
The maintenance period is five to fifteen working days. After repair, in case of non-human damage, the warranty period is six to twelve months (according to the category of medical devices).
輸尿管腎鏡維修
Ureterorenoscope service
2、提供維修備用品(主機、主鏡)
2. Provide maintenance supplies (host and main mirror)
我公司承諾主機維修工期為十到十五個工作日,鏡子及周邊器械維修期為五到十個工作日。如有逾期,經雙方協商后,我公司可提供替用機。
Our company promises that the maintenance period of the main machine is ten to fifteen working days, and the maintenance period of the mirror and surrounding equipment is five to ten working days. In case of delay, our company can provide alternative machines after negotiation between both parties.
3、提供現場檢測服務
3. Provide on-site inspection service
雙方協商后,我們會提供上門服務,現場檢測所存在的問題。現場提供維修報告和確認。
After negotiation, we will provide door-to-door service to detect the problems on site. Provide maintenance report and confirm the price on site.
4、提供安裝培訓服務
4. Provide installation training services
我公司有經驗豐富的工程師數名,可提供內窺鏡安裝和售后服務。可進行醫院的上門安裝和售后。
Our company has several experienced engineers, who can provide endoscope installation and after-sales service. It can be used for door-to-door installation and after-sales service in the hospital.
5、內窺鏡產品回收及投放
5. Recovery and delivery of endoscope products
輸尿管腎鏡維修主機和主鏡高價回收,可針對醫院提供成套的主機和主鏡的合作投放。
The ureterorenoscope maintenance host and primary mirror can be recovered at a high price, and the hospital can provide a complete set of host and primary mirror for cooperation.
The realization of ureterorenoscope maintenance and the related contents of featured services are like this. You can follow our website at www.jiangrenyiliao Cn, for more information!