內窺鏡設備在使用過程中會常常出現破損現象,這是有點不可避免的,所以就要做好找原因以及處理的準備,那么內窺鏡設備表面出現破損怎么處理呢?下面來講講吧。
Endoscope equipment in the use of the process will often appear damaged phenomenon, which is a little inevitable, so we should be ready to find the cause and treatment, then the surface of the endoscope equipment damage how to deal with it? So let's talk about it.
從鏡柜中取出懸掛式內窺鏡時,需要一只手握住設備的操作部分,另一只手握住兩個軟管部分,以減少軟管的銳角彎曲。共焦激光等內窺鏡需要兩個人相互配合才能取出和放置。內窺鏡放置在鏡架上時,操作部位和導光塞不應擠壓軟管,尤其是頂點部分。
To remove the hanging endoscope from the cabinet, one hand holds the operating part of the device and the other hand holds the two hose parts to reduce the sharp Angle bending of the hose. Endoscopes such as confocal lasers require two people to work together to remove and place them. When the endoscope is placed on the frame, the operating part and light guide plug should not squeeze the hose, especially the apex part.
鏡架需要在一層放置內窺鏡,另一側放置其他尖銳器械。不要將內窺鏡和鋒利的器械混在一起。運輸時,需要在運輸工具下方放置較厚的巾,避免運輸。在此過程中,內窺鏡因碰撞而損壞。
The frame requires an endoscope on one side and other sharp instruments on the other. Don't mix the endoscope with sharp instruments. During transportation, a thick treatment towel should be placed under the transportation vehicle to avoid transportation. In the process, the endoscope was damaged by collision.
內窺鏡懸掛后,插入部分需要保持靜止和下垂,以防止其擺動。內窺鏡主體與本科室插入部的接觸部位應安裝泡沫,可有效緩沖沖擊。在進行手術前,醫護人員需要耐心地向患者解釋,盡量讓患者保持放松。
After the endoscope is suspended, the insertion part needs to remain still and droop to prevent it from swinging. Foam should be installed on the contact part between the main body of the endoscope and the insertion part of the undergraduate room to effectively cushion the impact. Before the operation, medical staff need to patiently explain to the patient, try to keep the patient relaxed.
醫護人員在對患者進行手術時,需要密切觀察,了解口墊的固定狀態。如果有緊急情況,需要提醒他們退出內窺鏡。待患者病情穩定后,需要再次插入內窺鏡。
When performing surgery on patients, medical staff need to observe closely to understand the fixation state of the mouth pad. If there is an emergency, they need to be reminded to exit the endoscope. When the patient stabilizes, the endoscope needs to be inserted again.
橡膠件長時間使用后,會出現相應的磨損。操作者在進出鏡片時應盡量避免牙墊與橡膠接觸。內窺鏡不應放置在帶有尖銳器械的罐中進行和清潔。
There will be corresponding wear and tear after rubber parts are used for a long time. The operator should try to avoid contact between the tooth pad and rubber when entering or leaving the lens. Endoscopes should not be disinfected and cleaned in POTS with sharp instruments.
為減少
內窺鏡設備維修的損壞,需遵循科室的操作原則,操作前需仔細檢查附件的性能,如果遇到相應的阻力,需要先松開角度再扭動。使用內窺鏡插入部分時,需要將其拉直,然后穿過以減少管道中的開口,損壞后不能再次使用。
In order to reduce the damage of endoscopic equipment maintenance, it is necessary to follow the operating principles of the department. Before operation, the performance of the accessories should be carefully checked. If there is corresponding resistance, it is necessary to loosen the Angle and then twist. When using the endoscope insert section, it needs to be straightened and then passed through to reduce openings in the pipe, and cannot be used again if damaged.
內窺鏡設備表面出現破損怎么處理?以上就是使用時避免內窺鏡出現破損的操作,如果您正在使用期間可以一看。想了解更多關于該設備的內容,可以來我們網站
www.veeker.xyz了解哦!
Endoscope equipment surface damage how to deal with? The above is the operation to avoid the damage of the endoscope when using it, if you are using it can have a look. To learn more about the device, you can visit our website www.veeker.xyz!